Central Roof Reference

For more information contact us: 514-237-5103

Assembly No.: 1061-A-TPO SW AD
Assembly Owner: Carlisle
Reference link:
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-1.7 KPA ( -35 PSF ) -2.5 KPA ( -52 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO PARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Carlisle TPO Spectro-Weld
Attachment Pattern
Carlisle Bonding Adhesive AQUA-Base 120
Adhered
Carlisle TPO Bonding adhesive
Adhered
Carlisle Low VOC Bonding adhesive 1168
Adhered
Carlisle TPO Sure-Weld 1.1 mm to 2.1 mm (45 mil to 80 mil)
Attachment Pattern
Carlisle TPO Bonding adhesive
Adhered
Carlisle Low VOC Bonding adhesive 1168
Adhered
Carlisle Bonding Adhesive AQUA-Base 120
Adhered
Carlisle TPO Sure-Weld Extra 1.1 mm to 2.1 mm (45 mil to 80 mil)
Attachment Pattern
Carlisle Low VOC Bonding adhesive 1168
Adhered
Carlisle TPO Bonding adhesive
Adhered
Carlisle Bonding Adhesive AQUA-Base 120
Adhered

Base Insulation (Required)

Hunter Panels H-Shield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 screw/vis per/par .372 m2 (4' ca.)
Mechanically Attached
Hunter Panels H-Shield CG 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 screw/vis per/par .372 m2 (4' ca.)
Mechanically Attached
Hunter Panels H-Shield HD Composite 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 screw/vis per/par .372 m2 (4' ca.)
Mechanically Attached
Carlisle Polyiso HP-H 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
#12 screw with round insulation plates 3"
1 screw per 0.372 m2 (4 ft.sq.)
Mechanically Attached
Carlisle SecurShield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 screw/vis per/par .372 m2 (4' ca.)
Mechanically Attached
Carlisle SecurShield HD Composite 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 screw/vis per/par .372 m2 (4' ca.)
Mechanically Attached

Vapor Barrier (Required)

Carlisle CCW 705
Attachment Pattern
Self-Adhered / Auto collante
Fully Adhered
Carlisle CCW 725
Attachment Pattern
Self-Adhered / Auto collante
Fully Adhered
Generic Polyethylene .15 mm(6 mil.)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Carlisle VapAir Seal 725 TR
Attachment Pattern
Self-adhered / Auto collante
Fully Adhered

Thermal Barrier (Optional)

Georgia-Pacific Gypsum DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Generic Gypsum roof board (1.22 m x 2.44 m 15.9 mm (4 ft x 8 ft x 5/8 in.))
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached

Decking (Required)

Generic Béton structural / Concrete min 2,500 psi
Attachment Pattern
Canwood Plywood 5/8''
Attachment Pattern
Generic Steeldeck 22g. Galvanized
Attachment Pattern
.76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi)
Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf)
Mechanically Attached
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca