Product Manufacturer Results Reset Search


1377-A-PVC Duro-Last - IW16/12-24 - TGFY7.R10128 - IWS # 2

Assembly Owner: Duro-Last inc

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-4.8 KPA ( -100 PSF ) -7.2 KPA ( -150 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO MARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Duro-Last inc PVC Duro-Last
Attachment Pattern
Duro-Last inc PVC Duro-Last EV
Attachment Pattern
Duro-Last inc PVC Duro-Tuff
Attachment Pattern
Generic Induction
Welded

Base Insulation (Required)

Duro-Last inc Duro-Guard ISO II H
Attachment Pattern
Duro-Last inc #14 screws Duro-Last HD and Duro-Last 3'' Metal Plates
6 fasteners / 4'x 8' (1 / 5.3 ft.sq.)
Mechanically Attached
Duro-Last inc Duro-Guard ISO II-G
Attachment Pattern
Duro-Last inc #14 screws Duro-Last HD and Duro-Last 3'' Metal Plates
6 fasteners / 4'x 8' (1 / 5.3 ft.sq.)
Mechanically Attached
Seaman Corporation (FiberTite) DURO-Guard ISO III-H
Attachment Pattern
Duro-Last inc Duro-Guard ISO-II-A
Attachment Pattern
Duro-Last inc #14 screws Duro-Last HD and Duro-Last 3'' Metal Plates
6 fasteners / 4'x 8' (1 / 5.3 ft.sq.)
Mechanically Attached
Duro-Last inc Duro-Guard ISO-III-A
Attachment Pattern
SFS Intec Dekfast #15 HS with Isoweld PVC 3'' plates
16 fasteners / 4'x 8' (1 / 2 ft.sq.) 12'' x 24'' staggered grid Minimum resistance 300 lbf (136 kg)
Mechanically Attached
OMG OMG Extra Heavy Duty Roofing Fastener #15 with RHINOBOND insulation plate
16 fasteners / 4'x 8' (1 / 2 ft.sq.) 12'' x 24'' staggered grid Minimum resistance 300 lbf (136 kg)
Mechanically Attached
Duro-Last inc Duro-Last #15 Extra Heavy Duty Drill Point with Duro-Bond ISO WELD 1302-1 plates
16 fasteners / 4'x 8' (1 / 2 ft.sq.) 12'' x 24'' staggered grid Minimum resistance 300 lbf (136 kg)
Mechanically Attached
Trufast Trufast #15 EHD Roofing fasteners with Trufast PVC IW plare
16 fasteners / 4'x 8' (1 / 2 ft.sq.) 12'' x 24'' staggered grid Minimum resistance 300 lbf (136 kg)
Mechanically Attached

Vapor Barrier (Optional)

Duro-Last inc Duro-Blue
Attachment Pattern
Generic Loose laid / en indépendance
Joints taped / joints tapés
Independance
Duro-Last inc Duro-Last Vapor Barrier
Attachment Pattern
Generic Self-Adhered / Auto collante
Fully Adhered

Thermal Barrier (Optional)

Generic Any UL Classified any Thickness
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached

Decking (Required)

Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF