Product Manufacturer Results Reset Search


1313-A-SBS Welded + CB AD6 + ISO AD6 - TGFY7.R9516 - #9

Assembly Owner: Holcim Elevate (Firestone)

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-3.0 KPA ( -63 PSF ) -4.5 KPA ( -95 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO AARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Holcim Elevate (Firestone) SBS FR Torch
Attachment Pattern
Holcim Elevate (Firestone) SBS Glass FR Torch
Attachment Pattern
Holcim Elevate (Firestone) SBS Premium FR Torch
Attachment Pattern
Holcim Elevate (Firestone) SBS Premium Torch
Attachment Pattern
Holcim Elevate (Firestone) SBS Torch
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded

Base Sheet Membrane (Required)

Holcim Elevate (Firestone) SBS Glass Torch Base
Attachment Pattern
Holcim Elevate (Firestone) SBS Glass Torch Base 1.5
Attachment Pattern
Holcim Elevate (Firestone) SBS Poly Torch Base
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded

Cover Board (Required)

Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Holcim Elevate (Firestone) I.S.O. Twin Pack Adhesive
Ribbons / Cordons 6'' o.c.
Adhered
Holcim Elevate (Firestone) I.S.O. Stick Insulation Adhesive
Ribbons / Cordons 6'' o.c.
Adhered
Holcim Elevate (Firestone) Twin-Jet
Ribbons / Cordons 6'' o.c.
Adhered

Base Insulation (Required)

Holcim Elevate (Firestone) ISO 95+ 25mm (1") à 203,2 mm (8")
Attachment Pattern
Holcim Elevate (Firestone) I.S.O. Twin Pack Adhesive
2 layers / 2 rangs Ribbons / Cordons 305 mm (12'')
Adhered
Holcim Elevate (Firestone) Resista 25mm (1") à 203,2 mm (8")
Attachment Pattern
Holcim Elevate (Firestone) I.S.O. Twin Pack Adhesive
Ribbons / Cordons 152 mm (6'')
Adhered

Vapor Barrier (Required)

Holcim Elevate (Firestone) BaseGard SA
Attachment Pattern
Generic Self-Adhered / Auto collante
Adhered
Holcim Elevate (Firestone) V-Force
Attachment Pattern
Generic Self-Adhered / Auto collante
Fully Adhered

Decking (Required)

Generic Béton structural / Concrete min 2,500 psi
Attachment Pattern
Canwood Plywood 5/8''
Attachment Pattern
Generic Steeldeck 22g. Galvanized
Attachment Pattern
Generic .76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi) -Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf)
Mechanically Attached

Surfacing (Optional)

Generic Any roofing coating
Attachment Pattern

Ply Sheet (Optional)

Holcim Elevate (Firestone) SBS Glass Torch Base
Attachment Pattern
Holcim Elevate (Firestone) SBS Glass Torch Base 1.5
Attachment Pattern
Holcim Elevate (Firestone) SBS Poly Torch Base
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF