Product Manufacturer Results Reset Search


1210-A-Thermglas IV Cold AD

Assembly Owner: Tremco

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-2.5 KPA ( -52 PSF ) -3.7 KPA ( -78 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MULTI PARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Tremco Thermglass Premium Type VI
Attachment Pattern
Tremco Thermglass Type IV
Attachment Pattern
Tremco THERMastic 80
2 plies / 2 plis at 25 - 30 lbs / square
Fully Adhered

Base Sheet Membrane (Required)

Tremco BURmastic Composite Ply
Attachment Pattern
Tremco THERMastic 80
Fully Adhered

Cover Board (Required)

ModulR TS ProtecRSS
Attachment Pattern
Tremco THERMastic 80
Fully Adhered
Rockwool Top Rock DD Plus, minimum 2'' thick/épaisseur
Attachment Pattern

Base Insulation (Required)

IKO Industries Ltd. IKOTherm III
Attachment Pattern
Tremco THERMastic 80
2 layers of 2'' / 2 rangs de 2''
Fully Adhered

Vapor Barrier (Required)

Tremco AVC Membrane
Attachment Pattern
Generic Self-Adhered / Auto collante
Adhered

Thermal Barrier (Required)

CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic #12 pre assembled with 3" plates
8 screws and plates by 4' x 8' board, maximum of 12'' from each corner / 8 vis et plaquettes par panneaux de 4' x 8' avec un maximum de 12' de chaque coins'
Mechanically Attached

Decking (Required)

Generic Steeldeck 22g. Galvanized
Attachment Pattern
.76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi)
Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf)
Mechanically Attached

Surfacing (Required)

Generic Gravel / Gravier
Attachment Pattern
Tremco THERMastic 80
25 - 30 lbs / square
Fully Adhered
Tremco BURmastic ROCK-IT (white)
5.0 gal. / square
Fully Adhered
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF