1710-A-EPDM MA 6-114 + CB MA 8/32
📏 Holcim Elevate (Firestone)
Référence: RubberGard MA
kpa: -1.4 kPa
kpa_tested: -2.2 kPa
psf: -30 psf
psf_tested: -45 psf
roof_system: mono
system_type: mars
deck_type: steel
📋 Pas de lien disponible
1750-A - PARS - TPO AD + CB AD12 + ISO MA8/32_ PRI SP-12
📏 Johns Manville
Référence: PARS TPO45 AD _PRI report / SP-12
kpa: -2.4 kPa
kpa_tested: -3.6 kPa
psf: -50 psf
psf_tested: -75 psf
roof_system: mono
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1750-B - PARS - TPO AD + CB AD12 + ISO MA24/32_ PRI SP-50
📏 Johns Manville
Référence: PARS TPO45 AD _PRI report / SP-50
kpa: -4.8 kPa
kpa_tested: -7.2 kPa
psf: -100 psf
psf_tested: -150 psf
roof_system: mono
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1751-A - AARS - TPO AD + CB AD12+ ISO AD12 + ISO AD12_PRI SP-13,14,15
📏 Johns Manville
Référence: AARS TPO45 AD_PRI report / SP-13,14,15
kpa: -2.8 kPa
kpa_tested: -4.2 kPa
psf: -58.3 psf
psf_tested: -87.5 psf
roof_system: mono
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1754-A - AARS - PVC AD + CB AD12+ ISO AD12 + ISO AD12_PRI SP-16,17
📏 Johns Manville
Référence: AARS PVC45 AD_PRI report / SP-16,17
kpa: -2.8 kPa
kpa_tested: -4.2 kPa
psf: -58.3 psf
psf_tested: -87.5 psf
roof_system: mono
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1758-A- MARS - TPO60 MA12-114 + ISO MA 8/32_SP-20
📏 Johns Manville
Référence: MARS - TPO MA 12-114_SPRI SP-20
kpa: -2.9 kPa
kpa_tested: -4.3 kPa
psf: -60 psf
psf_tested: -90 psf
roof_system: mono
system_type: mars
deck_type: steel
🔗 Voir l'assemblage
1758-B- MARS - TPO60 MA6-114 + ISO MA 8/32_SP-39
📏 Johns Manville
Référence: MARS - TPO MA 6-114_SPRI SP-39
kpa: -3.4 kPa
kpa_tested: -5.0 kPa
psf: -70 psf
psf_tested: -105 psf
roof_system: mono
system_type: mars
deck_type: steel
🔗 Voir l'assemblage
1759-A - PARS - EPDM45 AD + CB AD12+ISO AD12+TB MA16/32 _PRI SP-30
📏 Johns Manville
Référence: PARS - EPDM 45_ PRI report / SP-30
kpa: -3.2 kPa
kpa_tested: -4.8 kPa
psf: -67 psf
psf_tested: -100 psf
roof_system: mono
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1760-A - PARS - TPO AD + CB AD12 +ISO AD12 +TB MA16/32_ PRI SP-31,32,33
📏 Johns Manville
Référence: PARS TPO45 AD _PRI report / SP-31,32,33
kpa: -4.8 kPa
kpa_tested: -7.2 kPa
psf: -100 psf
psf_tested: -150 psf
roof_system: mono
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1763-A - PARS - PVC AD + CB AD12 +ISO AD12 +TB MA16/32_ PRI SP-34,35
📏 Johns Manville
Référence: PARS PVC50 AD _PRI report / SP-34,35
kpa: -4.8 kPa
kpa_tested: -7.2 kPa
psf: -100 psf
psf_tested: -150 psf
roof_system: mono
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1784-A_MB AD+CB AD6+ISO AD6+VB SA+TB AD6_SIP AARS-003-007-016
📏 Siplast
Référence: 1784-A MB CB AD16+ ISO AD6
kpa: -2.9 kPa
kpa_tested: -4.3 kPa
psf: -60 psf
psf_tested: -90 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1784-B_MB AD+CB AD6+ISO AD6+VB SA+TB AD6_SIP AARS-018
📏 Siplast
Référence: 1784-B MB CB AD16+ ISO AD6
kpa: -5.0 kPa
kpa_tested: -7.5 kPa
psf: -105 psf
psf_tested: -157.5 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1784-C-MB AD+CB AD6+ISO AD6+VB SA+TB AD6_SIP AARS-020
📏 Siplast
Référence: 1784-C MB CB AD16+ ISO AD6
kpa: -5.2 kPa
kpa_tested: -7.8 kPa
psf: -108.3 psf
psf_tested: -162.5 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1785-A-MB CAD+CB ADMA+TB MA16/32_SIP PARS-017-018
📏 Siplast
Référence: 1785_A - MB CAD+ CB ADMA+TB6/32
kpa: -2.9 kPa
kpa_tested: -4.3 kPa
psf: -60 psf
psf_tested: -90 psf
roof_system: bic
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1785-B-MB CAD+CB ADMA+TB MA16/32_SIP PARS-016
📏 Siplast
Référence: 1785_B - MB CAD+ CB ADMA+TB6/32
kpa: -5.7 kPa
kpa_tested: -8.6 kPa
psf: -120 psf
psf_tested: -180 psf
roof_system: bic
system_type: pars
deck_type: steel
🔗 Voir l'assemblage
1786-A-MB Hot AD+CB WFB Hot AD+ISO Hot AD+VB Hot AD+TB AD6_SIP AARS-004
📏 Siplast
Référence: 1786-A MB Hot Ad+ CB Hot AD
kpa: -3.6 kPa
kpa_tested: -5.4 kPa
psf: -75 psf
psf_tested: -112.5 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1787-A_MB AD+CB AD12+ISO AD12+VB SA+TB AD6_SIP AARS-013
📏 Siplast
Référence: 1787-A MB CB AD12+ ISO AD12
kpa: -4.3 kPa
kpa_tested: -6.5 kPa
psf: -90 psf
psf_tested: -135 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1788-A-MB CAD+CB AD12+ISO AD12+VB SA+TB AD12_SIP AARS-017
📏 Siplast
Référence: 1788-A MB CAD CB AD12+ ISO AD12
kpa: -2.9 kPa
kpa_tested: -4.3 kPa
psf: -60 psf
psf_tested: -90 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1788-B-MB CAD+CB AD12+ISO AD12+VB SA+TB AD12_SIP AARS-014
📏 Siplast
Référence: 1788-B MB CAD CB AD12+ ISO AD12
kpa: -4.3 kPa
kpa_tested: -6.5 kPa
psf: -90 psf
psf_tested: -135 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage
1790-A-MB CAD+CB AD6+ISO AD6+VB SA_SIP AARS-019
📏 Siplast
Référence: 1790-A MB CAD CB AD6+ ISO AD6
kpa: -5.7 kPa
kpa_tested: -8.6 kPa
psf: -128.9 psf
psf_tested: -180 psf
roof_system: bic
system_type: aars
deck_type: steel
🔗 Voir l'assemblage