Central Roof Reference

For more information contact us: 514-237-5103

Assembly No.: 1185-A-PVC SE 1.8 AD
Assembly Owner: Protan
Reference link: EXP-PRTL-216729-T1
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-2.9 KPA ( -60 PSF ) -4.3 KPA ( -90 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO PARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Protan PVC Protan SE 1.8
Attachment Pattern
Protan GCTech 2586
Fully Adhered
Protan Protan 4533
Fully Adhered

Cover Board (Required)

Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Trufast #14 DP pre assembled with 61 mm (2.4") Metal plate
12 screws and plates/ vis et plaquettes 73 mm x 73 mm (3" x 3") per 32 sq.ft Minimum resistance 258 Kg - 569 lbf
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Trufast #14 DP pre assembled with 61 mm (2.4") Metal plate
12 screws and plates/ vis et plaquettes 73 mm x 73 mm (3" x 3") per 32 sq.ft Minimum resistance 263 Kg - 568 lbf
Mechanically Attached

Base Insulation (Required)

Atlas Roofing AC Foam II 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Atlas Roofing AC Foam III 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Atlas Roofing AC Foam IV 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Johns Manville ENRGY 3 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Hunter Panels H-Shield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
IKO Industries Ltd. IKOTherm
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Fransyl Izolon HD Type II
Attachment Pattern
Fransyl Izolon type 1- 50,8 mm (2'') à 203,2 mm (8'')
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Fransyl Adphalt
Ribbons / Cordons 305mm (12'')
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached

Vapor Barrier (Required)

Lexuco 2010 corp. Permate Stick - 54’’ x 75’ (1,37 mm x 22,86 m)
Attachment Pattern
Generic Self-Adhered / Auto collante
Multigrip primer on gypsum board / Apprêt Multigrip sur panneau de gypse
Fully Adhered
Generic Polyethylene .15 mm(6 mil.)
Attachment Pattern
Generic Loose laid / en indépendance
Independance

Thermal Barrier (Optional)

Georgia-Pacific Gypsum DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2")
Attachment Pattern
Generic Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
Mechanically Attached
Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Generic Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
Mechanically Attached
CertainTeed  Gypsum Type X (1.22 m x 2.44 m 15.9 mm (4 ft x 8 ft x 5/8 in.))
Attachment Pattern
Generic Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
Mechanically Attached

Decking (Required)

Generic Béton structural / Concrete min 2,500 psi
Attachment Pattern
.
See manufacturer's recommandations / Voir les recommandations du manufacturier
None
Canwood Plywood 5/8''
Attachment Pattern
Minimum resistance (CSA S136.F04) - 2.09 kN (470pf)
Mechanically Attached
Generic Steeldeck 22g. Galvanized
Attachment Pattern
.76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi)
Minimum resistance : CSA S136.F04: 2.09 kN (470 lb)
Mechanically Attached
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca