Assembly No.: | 1185-A-PVC SE 1.8 AD |
Assembly Owner: | Protan |
Reference link: | EXP-PRTL-216729-T1 |
Security Factor | Observed On Test |
---|---|
-2.9 KPA ( -60 PSF ) | -4.3 KPA ( -90 PSF ) |
Roof System | System Type | Deck Type |
---|---|---|
MONO | PARS | Steel |
Protan | PVC Protan SE 1.8 |
---|
Attachment Pattern | |||
Protan | GCTech 2586 | Fully Adhered | |
Protan | Protan 4533 | Fully Adhered |
Georgia-Pacific Gypsum | DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4") |
---|
Attachment Pattern | |||
Trufast |
#14 DP pre assembled with 61 mm (2.4") Metal plate
12 screws and plates/ vis et plaquettes 73 mm x 73 mm (3" x 3") per 32 sq.ft
Minimum resistance 258 Kg - 569 lbf
|
Mechanically Attached |
CGC/USG | Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8") |
---|
Attachment Pattern | |||
Trufast |
#14 DP pre assembled with 61 mm (2.4") Metal plate
12 screws and plates/ vis et plaquettes 73 mm x 73 mm (3" x 3") per 32 sq.ft Minimum resistance 263 Kg - 568 lbf
|
Mechanically Attached |
Atlas Roofing | AC Foam II 25mm (1’’) à 203.2 mm (8’’) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered |
Atlas Roofing | AC Foam III 25mm (1’’) à 203.2 mm (8’’) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered |
Atlas Roofing | AC Foam IV 25mm (1’’) à 203.2 mm (8’’) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered |
Johns Manville | ENRGY 3 25mm (1’’) à 203.2 mm (8’’) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered |
Hunter Panels | H-Shield 25mm (1’’) à 203.2 mm (8’’) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered |
IKO Industries Ltd. | IKOTherm |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Fransyl | Izolon HD Type II |
---|
Attachment Pattern |
Fransyl | Izolon type 1- 50,8 mm (2'') à 203,2 mm (8'') |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Fransyl |
Adphalt
Ribbons / Cordons 305mm (12'')
|
Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Lexuco 2010 corp. | Permate Stick - 54’’ x 75’ (1,37 mm x 22,86 m) |
---|
Attachment Pattern | |||
Generic |
Self-Adhered / Auto collante
Multigrip primer on gypsum board / Apprêt Multigrip sur panneau de gypse
|
Fully Adhered |
Generic | Polyethylene .15 mm(6 mil.) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance |
Georgia-Pacific Gypsum | DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2") |
---|
Attachment Pattern | |||
Generic |
Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
|
Mechanically Attached |
Georgia-Pacific Gypsum | DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4") |
---|
Attachment Pattern | |||
Generic |
Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
|
Mechanically Attached |
CertainTeed | Gypsum Type X (1.22 m x 2.44 m 15.9 mm (4 ft x 8 ft x 5/8 in.)) |
---|
Attachment Pattern | |||
Generic |
Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
|
Mechanically Attached |
CGC/USG | Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8") |
---|
Attachment Pattern | |||
Generic |
Drywall screws # 8 - 1 1/4''
6 screws and plates per 32 s.f. / 6 vis et plaquettes par 32 pi.ca.
|
Mechanically Attached |
Generic | Béton structural / Concrete min 2,500 psi |
---|
Attachment Pattern | |||
.
See manufacturer's recommandations / Voir les recommandations du manufacturier
|
None |
Canwood | Plywood 5/8'' |
---|
Attachment Pattern | |||
Minimum resistance (CSA S136.F04) - 2.09 kN (470pf) | Mechanically Attached |
Generic | Steeldeck 22g. Galvanized |
---|
Attachment Pattern | |||
.76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi)
Minimum resistance : CSA S136.F04: 2.09 kN (470 lb)
|
Mechanically Attached |
The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.
Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.
The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.
For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.
The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.
All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.
All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.
It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.
The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.
This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca