Product Manufacturer Results Reset Search


1275-A TRA - Tremlar - TGFY7.R6692 - #27-28

Assembly Owner: Tremco

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-6.0 KPA ( 125 PSF ) -9.0 KPA ( -187 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO AARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Tremco TRA Elastomeric Sheeting
Attachment Pattern
Tremco Trem-Lar LRM-H
2.0 gal/ square. Min. 4-inch wide laps sealed in-lap with "Trem-Lar® LRM-H", then apply "Trem-Lar® LRM-H", reinforced with 6-inch wide BURMESH, over all laps such that the reinforced "Trem-Lar® LRM-H" extends 2-3 inch on either side of the leading edge
Fully Adhered

Cover Board (Required)

Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
CGC/USG Securock Cement Roof Board
Attachment Pattern
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Royal Adhesives & Sealants Millennium One Step
Ribbons / Cordons 12'' o.c. / c.c. or Primer Toluene mixed Trem-Lar LRM-H (32 oz / gallon) When on structural concrete
Adhered
Tremco Tremco LR Adhesive
Ribbons / Cordons 12'' o.c. / c.c. or Primer Toluene mixed Trem-Lar LRM-H (32 oz / gallon) When on structural concrete
Adhered
Tremco Low Rise Foam Insulation Adhesive
Ribbons / Cordons 12'' o.c. / c.c. or Primer Toluene mixed Trem-Lar LRM-H (32 oz / gallon) When on structural concrete
Adhered
Royal Adhesives & Sealants Millenium PG-1 Pump Grade Adhesive
Ribbons / Cordons 12'' o.c. / c.c. or Primer Toluene mixed Trem-Lar LRM-H (32 oz / gallon) When on structural concrete
Adhered

Decking (Required)

Generic Béton structural / Concrete min 2,500 psi
Attachment Pattern
If concrete/béton no need of coverboard / pas besoin de panneau support
None
Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF