1168-A-UltraPly TPO AD + CB MA12/32

Assembly Owner: Holcim Elevate (Firestone)

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-3.2 KPA ( -67 PSF ) -4.8 KPA ( -100 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO MARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Holcim Elevate (Firestone) UltraPly TPO membrane
Attachment Pattern
Holcim Elevate (Firestone) Heavy Duty Fastener with 3'' plate
Spaced/espace 12'' o.c./ c.c.- 144'' o.c. / c.c.
Mechanically Attached

Cover Board (Optional)

Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Holcim Elevate (Firestone) ISOGard HD Composite
Attachment Pattern
Georgia-Pacific Gypsum SECUROCK Glass-MAt Roof Board
Attachment Pattern
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 fastener / ancrage 6.4 .f. / pi.ca.
Mechanically Attached

Base Insulation (Required)

IKO Industries Ltd. ISO 95+ GL 25mm (1") à 203,2 mm (8")
Attachment Pattern
Holcim Elevate (Firestone) Resista 25mm (1") à 203,2 mm (8")
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 fastener / ancrage 6.4 .f. / pi.ca.
Mechanically Attached

Vapor Barrier (Required)

Holcim Elevate (Firestone) V-Force
Attachment Pattern
Generic Self-Adhered / Auto collante
Fully Adhered

Thermal Barrier (Optional)

Generic Any UL Classified any Thickness
Attachment Pattern

Decking (Required)

Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Generic .76 mm (0.03") - yield/âme 276 MPa (40ksi) - tensile/résistance 358 MPa (52 ksi) -Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf)
Mechanically Attached