Product Manufacturer Results Reset Search


1348-A- EPDM/PVC - AD-12/32 - TGFY7.R8103 - #AD5

Assembly Owner: Carlisle

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-3.2 KPA ( -67 PSF ) -4.8 KPA ( -100.5 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO PARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Carlisle EPDM - Sure-Seal AFX 90-105
Attachment Pattern
Carlisle EPDM - Sure-Seal FleeceBACK
Attachment Pattern
Carlisle EPDM - Sure-Seal FR
Attachment Pattern
Carlisle EPDM - Sure-White
Attachment Pattern
Carlisle EPDM - Sure-White Fleeceback
Attachment Pattern
Carlisle EPDM Sure-Tough 1.1 mm - 1.9 mm ( 45 - 90 mil)
Attachment Pattern
Carlisle PVC - Sure-Flex
Attachment Pattern
Carlisle PVC - Sure-Flex Fleeceback
Attachment Pattern
Carlisle PVC - Sure-Flex KEE FRS Fleeceback
Attachment Pattern
Carlisle PVC - Sure-Flex KEE HP
Attachment Pattern
Carlisle TPO - Sure-Weld AFX
Attachment Pattern
Carlisle TPO - Sure-Weld Fleeceback
Attachment Pattern
Generic Asphalt oxyded
25 lbs/square
Fully Adhered
Carlisle Fast 100 LV
Ribbons/Cordons 6'' o.c../c.c.
Adhered
Carlisle Flexible Fast Adhesive
Ribbons/Cordons 6'' o.c../c.c.
Adhered
Carlisle Fast Dual Tank Adhesive
Ribbons/Cordons 6'' o.c../c.c.
Adhered
Carlisle Bonding adhesive 90-8-30A
1.67 gal/square
Fully Adhered
Carlisle CAV-GRIP III Adhesive/Primer
1.67 gal/square
Fully Adhered
Carlisle Low VOC PVC Bonding adhesive
1.67 gal/square
Fully Adhered
Carlisle TPO Spectro-Weld
Attachment Pattern
Carlisle TPO Sure-Weld 1.1 mm to 2.1 mm (45 mil to 80 mil)
Attachment Pattern
Carlisle TPO Sure-Weld HS 1.1 mm to 2.1 mm (45 mil to 80 mil)
Attachment Pattern

Cover Board (Required)

CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Carlisle Insulfast Fasteners & Plates
1 per 2.67s.f. / pi.ca. (12 per 4x8 / 6 per 4x4)
Mechanically Attached
Carlisle SecurShield HD Composite 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern

Base Insulation (Required)

Carlisle InsulBase Polyiso
Attachment Pattern
Carlisle Polyiso HP-H 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Carlisle SecurShield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Carlisle SecurShield HD Composite 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Carlisle Fast 100 LV
Ribbons/Cordons 6'' o.c../c.c. on top flanges of steel deck or 12'' o.c./c.c. on thermal barrier or insulation
Adhered
Carlisle Flexible Fast Adhesive
Ribbons/Cordons 6'' o.c../c.c. on top flanges of steel deck or 12'' o.c./c.c. on thermal barrier or insulation
Adhered

Vapor Barrier (Required)

Carlisle 725TR Self-Adhering Air and Vapor Barrier
Attachment Pattern
Generic Polyethylene .15 mm(6 mil.)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Soprema Sopravap’R
Attachment Pattern
Generic Self-Adhered / Auto collante
With CavGrip primer on steel deck
Fully Adhered
Carlisle VapAir Seal MD
Attachment Pattern
Generic Self-Adhered / Auto collante
Adhered

Thermal Barrier (Optional)

Generic Any UL Classified any Thickness
Attachment Pattern
Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Carlisle Fast 100 LV
Ribbons/Cordons 6'' o.c../c.c. On CavGrip Primer applied 1 800s.f. per cylinder
Adhered
Carlisle Flexible Fast Adhesive
Ribbons/Cordons 6'' o.c../c.c. On CavGrip Primer applied 1 800s.f. per cylinder
Adhered
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern

Decking (Required)

Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
CavGrip primer
1 800 s.f. per cylinder
Mechanically Attached
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.