Product Manufacturer Results Reset Search


1371-A -AARS-Kee Hot-applied - SMN-AARS-2-4

Assembly Owner: Seaman Corporation (FiberTite)

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-3.4 KPA ( -70 PSF ) -5.0 KPA ( -105 PSF )

Assembly Characteristics

Roof System System Type Deck Type
MONO AARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Seaman Corporation (FiberTite) FiberTite
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite FB
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite SM
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite SM FB
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite XT
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite XT FB
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite Xtreme
Attachment Pattern
Seaman Corporation (FiberTite) FTR 190e
0.5 gal./square
Fully Adhered
Seaman Corporation (FiberTite) FTR 290
1 gal./square
Fully Adhered
Seaman Corporation (FiberTite) FTR 390
1 gal./square
Fully Adhered
ICP Adhesives & Sealants Polyset CR-20
Spatter application
Fully Adhered
Seaman Corporation (FiberTite) FiberTite XTreme FB
Attachment Pattern

Upper Insulation (Required)

Atlas Roofing AC Foam II 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Seaman Corporation (FiberTite) FTR-Value
Attachment Pattern
Seaman Corporation (FiberTite) FTR-Value H
Attachment Pattern
Hunter Panels H-Shield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Lexuco 2010 corp. Isolex
Attachment Pattern
Generic Asphalt oxyded
Type II or IV - 25-30 lbs/square
Fully Adhered

Base Insulation (Optional)

Atlas Roofing AC Foam II 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Seaman Corporation (FiberTite) FTR-Value
Attachment Pattern
Seaman Corporation (FiberTite) FTR-Value H
Attachment Pattern
Hunter Panels H-Shield 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Lexuco 2010 corp. Isolex
Attachment Pattern
Fransyl ISOZOL EPS
Attachment Pattern
Atlas Roofing ThermalStar TS
Attachment Pattern
Generic Asphalt oxyded
Type III or IV - 25-30 lbs/square
Fully Adhered

Vapor Barrier (Required)

Seaman Corporation (FiberTite) FiberTite-SBS 190 TG Base
Attachment Pattern
Seaman Corporation (FiberTite) FiberTite-SBS TG Base
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Primer ASTM D41, 0.5 gal./square
Welded

Thermal Barrier (Optional)

CGC/USG Structural Panel Concrete Roof Deck
Attachment Pattern
Seaman Corporation (FiberTite) FTR-601 PG
Ribbons / Cordons 6'' o.c. On steel deck
Adhered
Seaman Corporation (FiberTite) FTR-601
Ribbons / Cordons 6'' o.c. On steel deck
Adhered
Royal Adhesives & Sealants Millennium One Step
Ribbons / Cordons 6'' o.c. On steel deck
Adhered
Royal Adhesives & Sealants Millenium PG-1 Pump Grade Adhesive
Ribbons / Cordons 6'' o.c. On steel deck
Adhered
Lexuco 2010 corp. Insultac II
Ribbons / Cordons 6'' o.c. On steel deck
Adhered

Decking (Required)

Generic Béton structural / Concrete min 2,500 psi
Attachment Pattern
Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF