Product Manufacturer Results Reset Search
Assembly Owner: Seaman Corporation (FiberTite)
The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.
Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.
The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.
For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.
The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.
All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.
All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.
It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.
The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.
This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca
Security Factor | Observed On Test |
---|---|
-2.4 KPA ( -50 PSF ) | -3.6 KPA ( -75 PSF ) |
Roof System | System Type | Deck Type |
---|---|---|
MONO | AARS | Steel |
Seaman Corporation (FiberTite) | FiberTite |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite FB |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite SM |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite SM FB |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite XT |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite XT FB |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite Xtreme |
---|
Attachment Pattern | |||
Seaman Corporation (FiberTite) |
FTR 190e
0.5 gal./square
|
Fully Adhered | |
Seaman Corporation (FiberTite) |
FTR 290
1 gal./square
|
Fully Adhered | |
Seaman Corporation (FiberTite) |
FTR 390
1 gal./square
|
Fully Adhered | |
ICP Adhesives & Sealants |
Polyset CR-20
Spatter application
|
Fully Adhered |
Seaman Corporation (FiberTite) | FiberTite XTreme FB |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FTR-Value |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FTR-Value H |
---|
Attachment Pattern |
Lexuco 2010 corp. | Isolex |
---|
Attachment Pattern | |||
Seaman Corporation (FiberTite) |
FTR-601
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Seaman Corporation (FiberTite) |
FTR-601 PG
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Royal Adhesives & Sealants |
Millennium One Step
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Royal Adhesives & Sealants |
Millenium PG-1 Pump Grade Adhesive
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Lexuco 2010 corp. |
Insultac II
Ribbons / Cordons 12'' o.c.
|
Adhered |
Seaman Corporation (FiberTite) | FTR-Value |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FTR-Value H |
---|
Attachment Pattern |
Fransyl | ISOZOL EPS |
---|
Attachment Pattern |
Atlas Roofing | ThermalStar TS |
---|
Attachment Pattern | |||
Seaman Corporation (FiberTite) |
FTR-601
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Seaman Corporation (FiberTite) |
FTR-601 PG
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Royal Adhesives & Sealants |
Millennium One Step
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Royal Adhesives & Sealants |
Millenium PG-1 Pump Grade Adhesive
Ribbons / Cordons 12'' o.c.
|
Adhered | |
Lexuco 2010 corp. |
Insultac II
Ribbons / Cordons 12'' o.c.
|
Adhered |
Seaman Corporation (FiberTite) | FiberTite-SBS 190 TG Base |
---|
Attachment Pattern |
Seaman Corporation (FiberTite) | FiberTite-SBS TG Base |
---|
Attachment Pattern | |||
Generic |
Torched-Applied / Thermosoudé
Primer ASTM D41, 0.5 gal./square
|
Welded |
Seaman Corporation (FiberTite) | VaporTite |
---|
Attachment Pattern | |||
Generic |
Self-Adhered / Auto collante
Primer Elastocol Stick Zero 1 gal./square
|
Fully Adhered |
CGC/USG | Structural Panel Concrete Roof Deck |
---|
Attachment Pattern | |||
Seaman Corporation (FiberTite) |
FTR-601 PG
Ribbons / Cordons 6'' o.c.
On steel deck
|
Adhered | |
Seaman Corporation (FiberTite) |
FTR-601
Ribbons / Cordons 6'' o.c.
On steel deck
|
Adhered | |
Royal Adhesives & Sealants |
Millennium One Step
Ribbons / Cordons 6'' o.c.
On steel deck
|
Adhered | |
Royal Adhesives & Sealants |
Millenium PG-1 Pump Grade Adhesive
Ribbons / Cordons 6'' o.c.
On steel deck
|
Adhered | |
Lexuco 2010 corp. |
Insultac II
Ribbons / Cordons 6'' o.c.
On steel deck
|
Adhered |
Generic | Steel min. 22 MSG and min. yield strength 40 ksi |
---|
Attachment Pattern |