Product Manufacturer Results Reset Search


1278-A-Polyglass HT Base 650 - MA12 - TGFY7.R14571 - #1

Assembly Owner: Polyglass USA inc.

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-4.8 KPA ( -100 PSF ) -7.2 KPA ( -150 PSF )

Assembly Characteristics

Roof System System Type Deck Type
BIC MARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Polyglass USA inc. Elastoflex S6 G
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. Elastoflex S6 G FR
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. Elastoflex VG FR
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. Elastoshield TS G FR
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. Elastoshield TS-G
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. PolyFresko G SBS
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Polyglass USA inc. PolyFresko G SBS FR
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded

Base Sheet Membrane (Required)

Polyglass USA inc. Polyglass HT Base 650
Attachment Pattern
Trufast #15 EHD with 2.4'' Barbed Metal Seam Plate
305 mm (12'') o.c. / c.c. Minimum resistance : 465 lb
Mechanically Attached
DEKFAST Dekfast DF-#15-PH3 with 2 3/4''-12B plates
305 mm (12'') o.c. / c.c. Minimum resistance : 465 lb
Mechanically Attached

Cover Board (Optional)

Georgia-Pacific Gypsum DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2")
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 fastener per 5.33 ft.sq / 1 ancrage par 5.33 pi.c.a
Mechanically Attached
Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 fastener per 5.33 ft.sq / 1 ancrage par 5.33 pi.c.a
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic #12 pre-assembled 3" plates
1 fastener per 5.33 ft.sq / 1 ancrage par 5.33 pi.c.a
Mechanically Attached

Base Insulation (Required)

Generic Any UL Classified any Thickness
Attachment Pattern
Generic #12 pre-assembled 3" plates
6 fasteners / ancrages per 4' x 8' 1 fastener per 5.33 ft.sq / 1 ancrage par 5.33 pi.c.a
Mechanically Attached

Vapor Barrier (Required)

Polyglass USA inc. SPAR-Marathon Vapor Barrier
Attachment Pattern
Generic Loose laid / en indépendance
Laps Sealed with / Sceller les joints avec : Spar-Marathon VP Barrier
Independance

Thermal Barrier (Optional)

Georgia-Pacific Gypsum DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Georgia-Pacific Gypsum DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
Generic Gypsum roof board (1.22 m x 2.44 m 15.9 mm (4 ft x 8 ft x 5/8 in.))
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached
CGC/USG Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8")
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Generic See manufacturer / Voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached

Decking (Required)

Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.