Product Manufacturer Results Reset Search
Assembly Owner: Holcim Elevate (Firestone)
The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.
Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.
The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.
For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.
The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.
All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.
All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.
It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.
The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.
This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca
Security Factor | Observed On Test |
---|---|
-3.2 KPA ( -67 PSF ) | -4.8 KPA ( -100 PSF ) |
Roof System | System Type | Deck Type |
---|---|---|
MONO | MARS | Steel |
Holcim Elevate (Firestone) | EcoWhite EPDM Membrane |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
#14 pre-assemble Heavy Duty (W56-RAC-4007)
With / Avec QuickSeam R.M.A. Strip - Spacing/espacement 1828mm (72'') - 305mm (12'') 0.c. / c.c.
Minimum resistance: 272.2 Kg or/ou 600lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | RubberGard EPDM FR Membrane |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
#14 pre-assemble Heavy Duty (W56-RAC-4007)
With / Avec QuickSeam R.M.A. Strip - Spacing/espacement 1828mm (72'') - 305mm (12'') 0.c. / c.c. Minimum resistance: 272.2 Kg or/ou 600lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | RubberGard Max Membrane EPDM |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
#14 pre-assemble Heavy Duty (W56-RAC-4007)
With / Avec QuickSeam R.M.A. Strip - Spacing/espacement 1828mm (72'') - 305mm (12'') 0.c. / c.c. Minimum resistance: 272.2 Kg or/ou 600lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | RubberGard MAX PT |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
#14 pre-assemble Heavy Duty (W56-RAC-4007)
With / Avec QuickSeam R.M.A. Strip - Spacing/espacement 1828mm (72'') - 305mm (12'') 0.c. / c.c. Minimum resistance: 272.2 Kg or/ou 600lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | RubberGard Platinum EPDM Membrane |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
#14 pre-assemble Heavy Duty (W56-RAC-4007)
With / Avec QuickSeam R.M.A. Strip - Spacing/espacement 1828mm (72'') - 305mm (12'') 0.c. / c.c. Minimum resistance: 272.2 Kg or/ou 600lb
|
Mechanically Attached |
Georgia-Pacific Gypsum | DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2") |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
HailGard Heavy Duty (HD) Fastener
12 screw/fixations per 32 f.s. / pi.ca.
minimum resistance : 340 kg or/ou 749.4 lb
|
Mechanically Attached |
Georgia-Pacific Gypsum | DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4") |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
HailGard Heavy Duty (HD) Fastener
12 screw/fixations per 32 f.s. / pi.ca. minimum resistance : 340 kg or/ou 749.4 lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | HailGard Composite Board 6 mm (1/4") - 15.9 mm (5/8") |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
HailGard Heavy Duty (HD) Fastener
12 screw/fixations per 32 f.s. / pi.ca. minimum resistance : 340 kg or/ou 749.4 lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | ISOGard HD Cover Board 12.7 mm (1/2") |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
HailGard Heavy Duty (HD) Fastener
12 screw/fixations per 32 f.s. / pi.ca. minimum resistance : 340 kg or/ou 749.4 lb
|
Mechanically Attached |
CGC/USG | Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8") |
---|
Attachment Pattern | |||
Holcim Elevate (Firestone) |
HailGard Heavy Duty (HD) Fastener
12 screw/fixations per 32 f.s. / pi.ca. minimum resistance : 340 kg or/ou 749.4 lb
|
Mechanically Attached |
Holcim Elevate (Firestone) | ISO 95+ 25mm (1") à 203,2 mm (8") |
---|
Attachment Pattern | |||
Generic |
Loose laid / en indépendance
Any of them / Au choix
|
Independance | |
Generic |
See manufacturer / Voir manufacturier
Any of them / Au choix
|
Adhered | |
Generic |
See manufacturer / Voir manufacturier
Any of them / Au choix
|
Mechanically Attached |
Holcim Elevate (Firestone) | Resista 25mm (1") à 203,2 mm (8") |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Holcim Elevate (Firestone) | BaseGard SA |
---|
Attachment Pattern | |||
Generic | Self-Adhered / Auto collante | Fully Adhered |
Generic | Kraft paper |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance |
Generic | Polyethylene .15 mm(6 mil.) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance |
Holcim Elevate (Firestone) | V-Force |
---|
Attachment Pattern | |||
Generic | Self-Adhered / Auto collante | Fully Adhered |
Georgia-Pacific Gypsum | DensDeck 1200 mm x 2440 mm x 12.7 mm (4' x 8' x 1/2") |
---|
Attachment Pattern | |||
Generic |
Loose laid / en indépendance
Any of them / Au choix
|
Independance | |
Generic |
See manufacturer / Voir manufacturier
Any of them / Au choix
|
Adhered | |
Generic |
See manufacturer / Voir manufacturier
Any of them / Au choix
|
Mechanically Attached |
Georgia-Pacific Gypsum | DensDeck Prime 1200 mm x 2440 mm x 6.4 mm (4' x 8' x 1/4") |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
CGC/USG | Securock Gypsum Fiber Roof Board 6.3 mm (1/4") - 17.9 mm (5/8") |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Generic | See manufacturer / Voir manufacturier | Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Generic | Steeldeck 22g. Galvanized |
---|
Attachment Pattern | |||
Generic | .76 mm (0.03") - yield/âme 230 MPa (33ksi) - tensile/résistance 310 MPa (45 ksi) -Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf) | Mechanically Attached |