Product Manufacturer Results Reset Search
Assembly Owner: Tremco
The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.
Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.
The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.
For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.
The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.
All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.
All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.
It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.
The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.
This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca
Security Factor | Observed On Test |
---|---|
-4.8 KPA ( -100 PSF ) | -7.2 KPA ( -150 PSF ) |
Roof System | System Type | Deck Type |
---|---|---|
BIC | MARS | Steel |
Tremco | POWERply APP FR |
---|
Attachment Pattern |
Tremco | POWERply SBS Deluxe HW |
---|
Attachment Pattern |
Tremco | POWERply Standard FR GT24 HW |
---|
Attachment Pattern |
Tremco | POWERply Standard FR H/W |
---|
Attachment Pattern | |||
Generic | Torched-Applied / Thermosoudé | Welded |
Tremco | POWERply HE Smooth (Base sheet) |
---|
Attachment Pattern | |||
Trufast |
#15 EHD with 2.4'' Barbed Metal Seam Plate
6'' o.c. within 5'' wide side laps, Scew length should be long enough to penetrate 3/4'' beyond deck
|
Mechanically Attached |
Generic | Any UL Classified any Thickness |
---|
Attachment Pattern | |||
Trufast |
#12 DP pre assembled with 76 mm (3") Metal Insulation plates
1 fasterner/ancrage per 5.33 ft.sq/ pi.ca.(6 screws by 4' x 8')
|
Mechanically Attached |
IKO Industries Ltd. | ISO 95+ GL 25mm (1") à 203,2 mm (8") |
---|
Attachment Pattern |
Rmax inc. | Multi-Max FA-3 |
---|
Attachment Pattern |
Rmax inc. | Thermaroof Plus-3 |
---|
Attachment Pattern |
Tremco | Trisotech |
---|
Attachment Pattern |
Tremco | Trisotech CGF |
---|
Attachment Pattern |
Tremco | Trisotech G |
---|
Attachment Pattern | |||
Trufast |
#12 DP pre assembled with 76 mm (3") Metal Insulation plates
1 fasterner/ancrage per 5.33 ft.sq/ pi.ca.(min.6 per 4x8)
|
Mechanically Attached |
Generic | Generic Self-Adhered vapor barrier |
---|
Attachment Pattern | |||
Generic | Self-Adhered / Auto collante | Fully Adhered |
Generic | Polyethylene .15 mm(6 mil.) |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Tremco |
Tremco Universal Adhesive
See manufacturer / Voir manufacturier
|
Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Generic | Any UL Classified any Thickness |
---|
Attachment Pattern | |||
Generic | Loose laid / en indépendance | Independance | |
Tremco |
Tremco Universal Adhesive
See manufacturer / Voir manufacturier
|
Adhered | |
Generic | See manufacturer / Voir manufacturier | Mechanically Attached |
Generic | Steel min. 22 MSG and min. yield strength 40 ksi |
---|
Attachment Pattern | |||
Generic | .76 mm (0.03") - yield/âme 276 MPa (40ksi) - tensile/résistance 358 MPa (52 ksi) -Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf) | Mechanically Attached |
Generic | Any roofing coating |
---|
Attachment Pattern | |||
Generic | See manufacturer / Voir manufacturier | Fully Adhered |
Tremco | POWERply APP Base Sheet |
---|
Attachment Pattern |
Tremco | POWERply APP Smooth |
---|
Attachment Pattern |
Tremco | POWERply Standard Smooth |
---|
Attachment Pattern | |||
Generic | Torched-Applied / Thermosoudé | Welded |