Product Manufacturer Results Reset Search


1249-A-PowerFast MA18 - TGFY7 - #3

Assembly Owner: Tremco

Terms and Conditions

The Central roofing reference did not realize any kind of tests and the results mentioned here, either it has carried out checks for accuracy. It offers no guarantee in that regard.

Each issued resistance result represents a specific assembly of a dynamic test laboratory ISO 17025 recognized and accredited according to the requirements of CSA A123.21.

The results should be read, seen and used in their entirety without any changes or substitutions of products or methods.

For equity products, no substitution or other change can not be done without a rigorous analysis according to specific requirements and validated by the Central roofing reference.

The optional products are optional; they do not affect in any way the result insofar as the anchor method is followed.

All terms used in this document such as "Ribbons" are terms that are part of the product technical reference and use in standard testing studied.

All the assembly data represent dynamic test results of roofing systems assembly; the assembly sheets are valid as per the manfacturer technical department keep those active and or, re-evaluations are planned to revise from the original date of the test.

It must be calculating -0.1 kPa (-0.015 psi) as the weaker result, everything bellows like -0.2 kPa (-0.03 psi) are stronger uplift wind resistance.

The Central Roofing Reference can not be held liable for any claim by the manufacturer in relation to the identification and CSA reserves the right to remove without notice and the specifications of the assembly.

This technical data assembly sheet is produce by Central Roof Reference, with copyright and subject to the Quebec legislation. All readers of this data sheet must insure themselves that she’s up to date and that she’s wasn’t avoid nether replace by a recent one. To validate, you must consult the Central Roof Reference website http://www.crt-csa.ca or to communicate with us by mail at info@crt-csa.ca

Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF

Minimal Pressure Rate

Security Factor Observed On Test
-1.4 KPA ( -30 PSF ) -2.2 KPA ( -45 PSF )

Assembly Characteristics

Roof System System Type Deck Type
BIC MARS Steel

Assembly Specifications

Cap Sheet Membrane (Required)

Tremco POWERply APP FR
Attachment Pattern
Tremco POWERply SBS Deluxe HW
Attachment Pattern
Tremco POWERply Standard FR GT24 HW
Attachment Pattern
Tremco POWERply Standard FR H/W
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded

Base Sheet Membrane (Required)

Tremco POWERply HE Smooth (Base sheet)
Attachment Pattern
Trufast #15 EHD with 2.4'' Barbed Metal Seam Plate
18'' in. o/c within the min. 4'' wide side laps. Screw length should be long enough to penetrate 3/4 in. beyond the bottom of the deck.
Mechanically Attached
Trufast Deep Dish Metal Batten Bar
18'' o.c. / c.c.
Mechanically Attached
Trufast Strait Line Metal Batten Bar
18'' o.c. / c.c.
Mechanically Attached

Cover Board (Optional)

Generic Any UL Classified any Thickness
Attachment Pattern
Trufast #12 DP pre assembled with 76 mm (3") Metal Insulation plates
1 fasterner/ancrage per 5.33 ft.sq/ pi.ca.
Mechanically Attached

Base Insulation (Required)

Atlas Roofing AC Foam II 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Atlas Roofing AC Foam III 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
Johns Manville ENRGY 3 25mm (1’’) à 203.2 mm (8’’)
Attachment Pattern
IKO Industries Ltd. ISO 95+ GL 25mm (1") à 203,2 mm (8")
Attachment Pattern
Rmax inc. Multi-Max FA-3
Attachment Pattern
Rmax inc. Thermaroof Plus-3
Attachment Pattern
Tremco Trisotech
Attachment Pattern
Tremco Trisotech CGF
Attachment Pattern
Tremco Trisotech G
Attachment Pattern
Trufast #12 DP pre assembled with 76 mm (3") Metal Insulation plates
1 fasterner/ancrage per 5.33 ft.sq/ pi.ca.(min.6 per 4x8)
Mechanically Attached

Vapor Barrier (Optional)

Generic Generic Self-Adhered vapor barrier
Attachment Pattern
Generic Self-Adhered / Auto collante
Fully Adhered
Generic Kraft paper
Attachment Pattern
Generic Polyethylene .15 mm(6 mil.)
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Tremco Tremco Universal Adhesive
See manufacturer / Voir manufacturier
Adhered
Generic Loose laid / en indépendance
Independance

Thermal Barrier (Optional)

Generic Any UL Classified any Thickness
Attachment Pattern
Generic Loose laid / en indépendance
Independance
Tremco Tremco Universal Adhesive
See manufacturer / voir manufacturier
Adhered
Generic See manufacturer / Voir manufacturier
Mechanically Attached

Decking (Required)

Generic Steel min. 22 MSG and min. yield strength 40 ksi
Attachment Pattern
Generic .76 mm (0.03") - yield/âme 276 MPa (40ksi) - tensile/résistance 358 MPa (52 ksi) -Minimum resistance (CSA S136.F04) - 2.09 kN (470 pf)
Mechanically Attached

Surfacing (Optional)

Generic Any roofing coating
Attachment Pattern
Generic See manufacturer / Voir manufacturier
Fully Adhered

Ply Sheet (Optional)

Tremco POWERply APP Base Sheet
Attachment Pattern
Tremco POWERply APP Smooth
Attachment Pattern
Tremco POWERply Standard Smooth
Attachment Pattern
Generic Torched-Applied / Thermosoudé
Welded
Please, checkmark the products you want and click the button to generate the pdf with your chosen products only.
Generate The PDF